Manufacturers Package Unit AC Inverter Central Air Conditioning Split 40 Ton Vrf Vrv System Air Conditioner

Discover the best deals on Manufacturers Package Unit AC, Inverter Central Air Conditioning, and more at our factory. Shop now for top-quality VRF and VRV systems!
Request a Quote

PRODUCTS DETAILS

  • Overview
  • WHY CHOOSE US
  • Products Line
  • Specification
  • Our Advantages
Overview

Basic Info.

Cooling/Heating
Cooling/Heating
Power Source
Electrical
Power Type
AC
Condition
New
Eer
3.32-4.72
Cop
3.56-5.5
Comperssors
DC Inverter
Outdoor Unit Aiflrow Rate dB(a)
45-63
Refrigerant
R410A
Cooling Capacity
8kw-61.5kw
Heating Capacity
9kw-69kw
Operating Temp. Range(Cooling/Heating)
-5-55/-20-30
Max.Esp
85
Power Supply
208-230V, 220-240V, 380-415V
Transport Package
Pallet, PE Bag, Carton, Corner Protector
Trademark
ZERO
Origin
China
Production Capacity
30000 Set/Month

Product Description

Manufacturers Package Unit AC Inverter Central Air Conditioning Split 40 Ton Vrf Vrv System Air Conditioner ZERO VRF is a powerful system for your next HVAC project if you are looking for cost effective solutions.
We offer one stop solution includes VRF drawing design, model selection, instalation material calculation, start up
guidance etc, equipments, installation material and other parts will be loaded all together in the same containers
directly ship to your job site, we make your VRF projects never been so easy.

WHY CHOOSE US

 

Manufacturers Package Unit AC Inverter Central Air Conditioning Split 40 Ton Vrf Vrv System Air Conditioner
1.Experience
More than 15 years of overseas HVAC project experience,with deep understanding of global markets.

 
2.Professional design
Our professional design team are ready to provide you a AC plan drawing based on your architecture blueprint, we will advise the
most suitable solution.


 
3.Professional selection
We can select the most suitable model for your project according to the drawings.
 
 
4.One-stop solution
The necessary installation material and other parts can be collected and loaded them all together directly ship to your job site,
which is truly one-stop solution.



5.Technical support
Professional technical support, worry-free after sales.

Manufacturers Package Unit AC Inverter Central Air Conditioning Split 40 Ton Vrf Vrv System Air Conditioner1.Project Drawing, building layout, equipment BOQ.
2.Project name: building name or building type, such as xxx office project, residential house project etc.
3.Expected shipping date of this project.
4.Project type: tender or self-owned.

Products Line

Manufacturers Package Unit AC Inverter Central Air Conditioning Split 40 Ton Vrf Vrv System Air Conditioner  8/10/12Hp          14/16HP                  18/20HP               22HP                          24HP                          26/28/30/32HP

13 BASIC MODULES (380V-3Ph-50/60Hz)
HP 8
10
12
14 16
18
20 22
Dimension (mm)
990*1740*845 1340*1740*845
Fan quantity 1 1 1 1 1 2 2 2
Compressor quantity 1 1 1 1 1 2 2 2
HP 24 26 28 30 32
Dimension (mm)
1990*1740*845
Fan quantity 2 2 2 2 2
Compressor quantity 2 2 2 2 2
Manufacturers Package Unit AC Inverter Central Air Conditioning Split 40 Ton Vrf Vrv System Air Conditioner

Specification

Type Mini VRF Large VRF
Capacity HP 3HP-12HP 8HP-22HP
Power supply V/Ph/Hz 220-240V/1PH/50Hz
208-230V/1PH/60Hz
380-415V/3PH/50Hz & 60Hz
208-230V/3PH/60Hz
380-415V/3PH/50Hz & 60Hz
Cooling Capacity kW 8KW~33.5KW 25.2KW-61.5KW
kBtu/h 27.3-60kBtu/h 86-209.8kBtu/h
Power input kW 5.78-14.4KW 17-27.65KW
EER kW/kW 3.32-3.69 3.02-4.72
Heating Capacity kW 9KW-37.5KW 27.4KW-69KW
kBtu/h 92-191kBtu/h 27.4KW-69KW
Power input kW 5.41-14KW 15.8-26.08KW
COP kW/kW 3.56-4.27 4.11-5.5
Comperssors Type - DC inverter
Fan motors Type - DC inverter
Max.ESP Pa 85 85
Refrigerant Type R410A
Aiflrow rate m³/h m³/h 3300-8000 15000-17000
  dB(A) dB(A) 45-60 58-63
Ambient temp Cooling ºC -5-50ºC -5-55ºC
  Heating ºC -20-30ºC -30-30ºC

Our Advantages

Manufacturers Package Unit AC Inverter Central Air Conditioning Split 40 Ton Vrf Vrv System Air Conditioner
LONG PIPE & HEIGHT DIFFERENCE
1.The total pipe length: 1000 m.
2.The longest pipe length: 200 /240m.
3.Height deference:Outdoor unit.
Above<90m<90m.
4.Outdoor unit below<110m.
5.Height difference between indoor units: 30m.
6.Length from first indoor distributor to last indoor unit 90 m.
7.Communication wire length can be upto 1000m.





CONTROLLERS AND SOFTWARE
SIMPLIFY CENTRALIZED CONTROLLER
Easy to install.Controller connects to outdoor units only.
1 Controller can control max. 100 indoor units.
Operation mode restriction.
Error or protection code display
Can control single unit or all units together
Manufacturers Package Unit AC Inverter Central Air Conditioning Split 40 Ton Vrf Vrv System Air Conditioner



INDOOR UNITS QUANTITY
Max. 100 Indoor units can be connected in ONE system.





WIRELESS REMOTE CONTROLLERS
Indoor unit address inquiry.
Indoor unit address setting.
Temperature setting.
Operation mode setting.
Fan speed setting.
Timer function.

 

Manufacturers Package Unit AC Inverter Central Air Conditioning Split 40 Ton Vrf Vrv System Air Conditioner
SERVICE WINDOW ON FRONT COVER
Thanks to the service window, checking outdoor
unit's status and setting is now easy, no need to
remove the front cover.







WIDE OUTDOOR OPERATION RANGE(380V)
Max.cooling operating temperature is up to 55°C.
Low ambient temperature of cooling mode can be downto-10ºC.

Manufacturers Package Unit AC Inverter Central Air Conditioning Split 40 Ton Vrf Vrv System Air Conditioner

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours