- Overview
- WHY CHOOSE US
- Products Line
- Specification
- Our Advantages
Basic Info.
Cooling/Heating
Cooling/Heating
Power Source
Electrical
Power Type
AC
Condition
New
Eer
3.32-4.72
Cop
3.56-5.5
Comperssors
DC Inverter
Outdoor Unit Aiflrow Rate dB(a)
45-63
Refrigerant
R410A
Cooling Capacity
8kw-61.5kw
Heating Capacity
9kw-69kw
Operating Temp. Range(Cooling/Heating)
-5-55/-20-30
Max.Esp
85
Power Supply
208-230V, 220-240V, 380-415V
Transport Package
Pallet, PE Bag, Carton, Corner Protector
Trademark
ZERO
Origin
China
Production Capacity
30000 Set/Month
Product Description
ZERO VRF is a powerful system for your next HVAC project if you are looking for cost effective solutions.
We offer one stop solution includes VRF drawing design, model selection, instalation material calculation, start up
guidance etc, equipments, installation material and other parts will be loaded all together in the same containers
directly ship to your job site, we make your VRF projects never been so easy.
INDOOR UNITS QUANTITY
Max. 100 Indoor units can be connected in ONE system.
WIRELESS REMOTE CONTROLLERS
Indoor unit address inquiry.
Indoor unit address setting.
Temperature setting.
Operation mode setting.
Fan speed setting.
Timer function. SERVICE WINDOW ON FRONT COVER
Thanks to the service window, checking outdoor
unit's status and setting is now easy, no need to
remove the front cover.
WIDE OUTDOOR OPERATION RANGE(380V)
We offer one stop solution includes VRF drawing design, model selection, instalation material calculation, start up
guidance etc, equipments, installation material and other parts will be loaded all together in the same containers
directly ship to your job site, we make your VRF projects never been so easy.
1.Experience
More than 15 years of overseas HVAC project experience,with deep understanding of global markets.
More than 15 years of overseas HVAC project experience,with deep understanding of global markets.
2.Professional design
Our professional design team are ready to provide you a AC plan drawing based on your architecture blueprint, we will advise the
most suitable solution.
Our professional design team are ready to provide you a AC plan drawing based on your architecture blueprint, we will advise the
most suitable solution.
3.Professional selection
We can select the most suitable model for your project according to the drawings.
We can select the most suitable model for your project according to the drawings.
4.One-stop solution
The necessary installation material and other parts can be collected and loaded them all together directly ship to your job site,
which is truly one-stop solution.
5.Technical support
Professional technical support, worry-free after sales.
The necessary installation material and other parts can be collected and loaded them all together directly ship to your job site,
which is truly one-stop solution.
5.Technical support
Professional technical support, worry-free after sales.
1.Project Drawing, building layout, equipment BOQ.
2.Project name: building name or building type, such as xxx office project, residential house project etc.
3.Expected shipping date of this project.
4.Project type: tender or self-owned.
8/10/12Hp 14/16HP 18/20HP 22HP 24HP 26/28/30/32HP
13 BASIC MODULES (380V-3Ph-50/60Hz)HP | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 |
Dimension (mm) | 990*1740*845 | 1340*1740*845 | ||||||
Fan quantity | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 |
Compressor quantity | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 |
HP | 24 | 26 | 28 | 30 | 32 |
Dimension (mm) | 1990*1740*845 | ||||
Fan quantity | 2 | 2 | 2 | 2 | 2 |
Compressor quantity | 2 | 2 | 2 | 2 | 2 |
Type | Mini VRF | Large VRF | ||
Capacity | HP | 3HP-12HP | 8HP-22HP | |
Power supply | V/Ph/Hz | 220-240V/1PH/50Hz 208-230V/1PH/60Hz 380-415V/3PH/50Hz & 60Hz | 208-230V/3PH/60Hz 380-415V/3PH/50Hz & 60Hz | |
Cooling | Capacity | kW | 8KW~33.5KW | 25.2KW-61.5KW |
kBtu/h | 27.3-60kBtu/h | 86-209.8kBtu/h | ||
Power input | kW | 5.78-14.4KW | 17-27.65KW | |
EER | kW/kW | 3.32-3.69 | 3.02-4.72 | |
Heating | Capacity | kW | 9KW-37.5KW | 27.4KW-69KW |
kBtu/h | 92-191kBtu/h | 27.4KW-69KW | ||
Power input | kW | 5.41-14KW | 15.8-26.08KW | |
COP | kW/kW | 3.56-4.27 | 4.11-5.5 | |
Comperssors | Type | - | DC inverter | |
Fan motors | Type | - | DC inverter | |
Max.ESP | Pa | 85 | 85 | |
Refrigerant | Type | R410A | ||
Aiflrow rate | m³/h | m³/h | 3300-8000 | 15000-17000 |
dB(A) | dB(A) | 45-60 | 58-63 | |
Ambient temp | Cooling | ºC | -5-50ºC | -5-55ºC |
Heating | ºC | -20-30ºC | -30-30ºC |
LONG PIPE & HEIGHT DIFFERENCE
1.The total pipe length: 1000 m.
2.The longest pipe length: 200 /240m.
3.Height deference:Outdoor unit. Above<90m<90m.
1.The total pipe length: 1000 m.
2.The longest pipe length: 200 /240m.
3.Height deference:Outdoor unit. Above<90m<90m.
4.Outdoor unit below<110m.
5.Height difference between indoor units: 30m.
6.Length from first indoor distributor to last indoor unit 90 m.
7.Communication wire length can be upto 1000m.
CONTROLLERS AND SOFTWARE
1 Controller can control max. 100 indoor units.
Operation mode restriction.
Error or protection code display
Can control single unit or all units together
5.Height difference between indoor units: 30m.
6.Length from first indoor distributor to last indoor unit 90 m.
7.Communication wire length can be upto 1000m.
CONTROLLERS AND SOFTWARE
SIMPLIFY CENTRALIZED CONTROLLER
Easy to install.Controller connects to outdoor units only. 1 Controller can control max. 100 indoor units.
Operation mode restriction.
Error or protection code display
Can control single unit or all units together
INDOOR UNITS QUANTITY
Max. 100 Indoor units can be connected in ONE system.
WIRELESS REMOTE CONTROLLERS
Indoor unit address inquiry.
Indoor unit address setting.
Temperature setting.
Operation mode setting.
Fan speed setting.
Timer function.
Thanks to the service window, checking outdoor
unit's status and setting is now easy, no need to
remove the front cover.
WIDE OUTDOOR OPERATION RANGE(380V)
Max.cooling operating temperature is up to 55°C.
Low ambient temperature of cooling mode can be downto-10ºC.